Mould Temperature Controller(Oil & Water)

The mold temperature controller circulates cooling fluid through the mold’s cooling circuits to provide equilibrium to the heat flux experienced by the mold for every cycle. It is common to run separate mold temperature controllers for each mold half. This set-up allows for greater process control and processability.

Temperature control units are used to preheat the mold and then to keep the mold at the temperature set point by circulating coolant (water or oil) through the mold. The coolant absorbs heat from the mold (which has absorbed heat from the hot plastic) and keeps the mold at proper temperature to solidify the plastic.

The function of a mold temperature controller is to push the coolant to flow and stabilize the coolant temperature. The main function of the pump in the mold temperature controller is to push the coolant to flow.

HF Series MTC provide maximum efficiency for all your processing applicaons. Owing to its advanced microprocessor controller display operation, our temperature controller provides stable temperature during the moulding process in various industries. Easy mobility, low maintenance and flawless performance are some of the characteristics of our controller. We are well known for complete reliability & excellent after Sales services.

  • Oil based system for maximum 150°C temperature and water based system for maximum 95°C temperature.
  • Digital display of set and actual value on screen.
  • High flow and high pressure powerful pump.
  • Easy to operate.
  • Dry running protection of pump by level monitoring device.
  • Automatic water refilling provision in water based unit.
  • Painted with P.U. paint.
  • Corrosion proof material in water line.
  • User friendly control and fault indication.
  • Overload protection of pump.
  • Audible alarm for fault indication.
Model HC-3 HC-6 HC-9 HC-12 HC-18 HCW-3 HCW-6 HCW-9 HCW-12 HCW-18
Circulating media Oil Oil Oil Oil Oil Water Water Water Water water
Heating capacity  kw 3 6 9 12 18 3 6 9 12 18
Maximum temperature degree 150 150 150 150 150 95 95 95 95 95
Nominal cooling capacity kw 20 20 20 28 28 20 20 20 28 28
Pump pressure bar 3.8 3.8 3.8 5.0 5.0 3.8 3.8 3.8 5.0 5.0
Pump motor kw 0.5 0.5 0.5 2.2 2.2 0.5 0.5 0.5 2.2 2.2
Flow rate lpm 65 65 65 100 100 65 65 65 100 100
Tank volume L 16 16 16 45 45 16 16 16 45 45
Weight kg 60 60 60 135 135 60 60 60 135 135
Dimentions HxWxD mm 680X354X825 1000X403X825 680X354X825 1000X354X825
Operating voltage 415V,50HZ,3 Phase
Control voltage 230 V

 

  • Injection moulding