Water Cooled Water Chiller

Water Cooled chillers are also used frequently to refrigerate facilities of all kinds, cooling products and machinery among other applications. Water Cooled chillers often are used with a cooling tower or adiabatic system. Water cooled chillers are generally smaller than air cooled chillers and for that reason can be placed indoors without as much need for ventilation.Water cooled chillers are also often used more effectively in high temperature areas as they are cooled using an external source.

This Chillers play an important role in many industries. They help keep medical machines running consistently, and they keep milk cool until it goes to markets. They assist in the pharmaceutical industry, the brewery industry, and in meat and poultry processing. If you’re looking for a chiller for your business, one of the things you’ll have to decide is whether you need an air-cooled chiller or a water-cooled chiller. 

Cooling capacity range from 17.5 kW to 462 kW. Hexacool process cooling Water Cooled Scroll Chillers are built with shell and tube condenser and evaporators which ensure high efficiencies and trouble-free operation. Redundancy models are made available in chillers of capacities 10 TR and upwards. Like the Air Cooled chillers, these come with two/three/four compressors that aid in energy efficient operation and equal aging of its components. 

Water-cooled chiller systems have a cooling tower, thus they feature higher efficiency than air-cooled chillers.

Water-cooled chillers are more efficient because they condense depending on the ambient temperature bulb temperature, which is lower than the ambient dry bulb temperature. The lower a chiller condenses, the more efficient it is.

  • Evaporator Strainer
  • Compressor (Scroll, Sealed, Reciprocating)
  • Brazed Plate Evaporator
  • Process Pump Pressure Gauge
  • Refrigerant (R22,R134A)
  • Scroll and Function buttons allow you to navigate the chiller’ s control parameters.
  • Selectable temperature control point; choose between To Process, From Process or Average.
  • Five status lights that show pump, hot – gas by pass, compressor, alarm and temperature units selection status.
  • Auto-tune capabilities allow to you optimize your chiller to achieve maximum efficiency
Cooling capacity range 17.5 kW to 462 kW
Fluid Soft Water + glycol solution
Refrigerant R134A/R22
Operating ambient temperature range +10 to + 50C
Best fluid outlet temperature 15degc
At ambient 35degc
∆T 5 Deg C
Condenser Type  Water-Cooled
Evaporator Typ Brazed Plate Heat Exchanger / Shell & Tube Heat Exchanger
Operating environment Indoor / Out door
Power supply 1 PH / 3 PH, 220V / 415 V, AC, 50/60 HZ
Fluid loop Open loop
Noise level < 85 db
Life expectancy 8-18 years
  • Pharmaceuticals
  • Chemicals
  • Automobile
  • Brewery
  • food and beverages
  • electro plating.